Cal Am 7112-051-071 FIBER OPTIC SIMPLEX PLUG, SIZE 1.25 inch  32mm, PORT 0.51 inch  - 0.71 inch  12.

Cal Am 7112-051-071 FIBER OPTIC SIMPLEX PLUG, SIZE 1.25 inch 32mm, PORT 0.51 inch - 0.71 inch 12.

Available*
Item # 52088552
Model # 7112-051-071
$129.60
Peac Financing financing available. Learn More
Qty:

* Notes on Availability:
If item is in stock, it will ship same day.
Lead times vary, contact us for more info.
(Images may not be of the actual item being sold.)

  • Product Description
  • You Might Also like
  • Recently Viewed
Generic
Class
Group
Type
Manufacturer
LOT
DUCT PLUG
Material and Supplies
Duct- Conduit
Closure Plugs
CAL AM Manufacturing
CA Prop 65 Warning Warning: This product can expose you to chemicals, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov

Product Description

Cal Am 7112-051-071 FIBER OPTIC SIMPLEX PLUG, SIZE 1.25 inch 32mm, PORT 0.51 inch - 0.71 inch 12.

Cal Am 7112-051-071 FIBER OPTIC SIMPLEX PLUG, SIZE 1.25 inch 32mm, PORT 0.51 inch - 0.71 inch 12.mm *** MINIMUM ORDER 20 ***

Cal Am 7112-051-071 FIBER OPTIC SIMPLEX PLUG SIZE 1.25 inch 32mm CONDUIT INNER DIA. 1.28 - 1.36 32.51 - 34.54 mm PORT 0.51 inch - 0.71 inch 12.mm Case Dimensions: 4 x 9 x 11 (inches) Case Weight 4 lbs.

*** MINIMUM ORDER 20 ***

-When the thermoplastic elastomer gasket is expanded, it creates a water and air-resistant seal - protecting datacenters from damaging environmental issues - Constructed of non-metallic, corrosion-resistant material, these plugs are long-lasting and cost-effective - Designed to split apart for easy retrofit around in-place cables

Note: When selecting a fiber optic simplex plug:

Determine the inside diameter of the duct and select the range of plugs. Determine the outside diameter of the cable (or inner duct) and select the correct plug in the range. Make sure you know the minimum internal diameter of the duct. Some ducts quoted at 50 mm (2 inch) internal diameter (nominal) might be only 48 mm (1.90 inch). Also, given the outside diameter, determine the minimum O.D. and the maximum wall thickness and calculate the minimum I.D. The actual cable (or inner duct) diameter must be determined. A quoted cable diameter of 15 mm (.60 inch) might be anywhere between 14 and 16 mm (.55 or .63 inches), depending on the manufacturer.