Klein Cl900 Digital Clamp Meter, Ac Auto-Range Trms, Low Impedance (Loz), 2000 Amp 092644692352
Available*
Item # 80020582
Model # CL900
$199.99
* Notes on Availability:
If item is in stock, it will ship same day.
Lead times vary, contact us for more info.
(Images may not be of the actual item being sold.)
- Product Description
- You Might Also like
- Recently Viewed
Generic
Class
Group
Type
Manufacturer
LOT
Power
Test Equipment
Electric Power
Voltage
Klein Tools
Warning: This product can expose you to chemicals, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.govProduct Description
Klein Cl900 Digital Clamp Meter, Ac Auto-Range Trms, Low Impedance (Loz), 2000 Amp 092644692352
Klein Cl900 Digital Clamp Meter, Ac Auto-Range Trms, Low Impedance (Loz), 2000 Amp 092644692352
P/N Cl900 Digital Clamp Meter Ac Auto-Range Trms Low Impedance (Loz) 2000 Amp Upc: 092644692352
Digital Clamp Meter Measures 2000A Ac/Dc, 1000V Ac/Dc, 60 Milliohm Rugged Klein Tough Meter Industrial Design Stands Up To Jobsite Demands; Built To Withstand A 6.6-Foot (2M) Drop Automatically Ranging True Root Mean Squared (Trms) Measurement Technology For Accuracy Cat Iv 600V, Cat Iii 1000V, Class 2, Double Insulation Safety Rating Backlit Display For Clear Visibility In Environments With Low Ambient Lighting Dedicated Mode For Capturing Inrush Current Non-Contact Voltage Tester Integrated Into The Clamp Low Impedance (Loz) Mode For Identifying And Eliminating Ghost Or Stray Voltages Audible Continuity, Capacitance, Diode Test, Frequency And Duty Cycle, Min/Max Feature, Data Hold Capability Test Leads Measure Ac/Dc Voltage, Resistance, Continuity, Frequency, Duty-Cycle, Capacitance And Diodes Clamp Measures Ac And Dc Current Powers Off Automatically After 30 Minutes Of Non-Use To Conserve Battery Life Low Battery Indicator And Easily Accessible Battery Compartment Includes Carrying Case (Instruction Manual), Straight Input Test Leads, And 2 X Aaa Batteries Can Be Used With Magnetic Hanger Cat. No. 69417 (Sold Separately)
Specifications Type: Clamp Meter
Application: Measures Current To 2000A Ac/Dc
Special Features: Low Impedance (Loz) Mode; Dedicated Mode For Capturing Inrush Current; Integrated
Non-Contact Voltage Tester Material: Plastic/Electronics Batteries: 2 X Aaa
Auto-Power Off: Yes Jaw Size: 2'' (5 Cm) Drop Protection: 6.6' (2 M) Display: 6000 Count Lcd
Functions: Audible Continuity, Capacitance, Diode Test, Frequency & Duty Cycle, Min/Max Feature, Data Hold Capability, Inrush Current, Low Impedance
Voltage: 1000V Ac/Dc Frequency: 500Khz Current: 2000A Ac/Dc Capacitance: 6000µf Ohms (Resistance): 60M?
Ac Voltage: 1000 Dc Voltage: 1000 Dc Polarity Indicator: Yes Dc Micro-Amp: No Ingress Protection: Ip40 Standard: Cat Iv 600V, Cat Iii 1000V
Included: Carrying Case, Instruction Manual, Straight Input Test Leads, Batteries
Overall Length: 10.39'' (26.4 Cm) Overall Height: 1.70'' (4.3 Cm) Overall Width: 3.90'' (9.9 Cm)
Weight: 17.6 Oz (499 G) Upc: 092644692352
Warnings Read, Understand, And Follow All Instructions, Cautions And Warnings Attached To And/Or Packed With All Test And Measurement Devices Before Each Use Before Each Use, Verify Meter Operation By Measuring A Known Voltage Or Current Never Use The Meter On A Circuit With Voltages That Exceed The Category Based Rating Of This Meter Always Adhere To Local And National Safety Codes. Use Personal Protective Equipment To Prevent Shock And Arc Blast Injury Where Hazardous Live Conductors Are Exposed
Klein Cl900 Digital Clamp Meter, Ac Auto-Range Trms, Low Impedance (Loz), 2000 Amp 092644692352
P/N Cl900 Digital Clamp Meter Ac Auto-Range Trms Low Impedance (Loz) 2000 Amp Upc: 092644692352
Digital Clamp Meter Measures 2000A Ac/Dc, 1000V Ac/Dc, 60 Milliohm Rugged Klein Tough Meter Industrial Design Stands Up To Jobsite Demands; Built To Withstand A 6.6-Foot (2M) Drop Automatically Ranging True Root Mean Squared (Trms) Measurement Technology For Accuracy Cat Iv 600V, Cat Iii 1000V, Class 2, Double Insulation Safety Rating Backlit Display For Clear Visibility In Environments With Low Ambient Lighting Dedicated Mode For Capturing Inrush Current Non-Contact Voltage Tester Integrated Into The Clamp Low Impedance (Loz) Mode For Identifying And Eliminating Ghost Or Stray Voltages Audible Continuity, Capacitance, Diode Test, Frequency And Duty Cycle, Min/Max Feature, Data Hold Capability Test Leads Measure Ac/Dc Voltage, Resistance, Continuity, Frequency, Duty-Cycle, Capacitance And Diodes Clamp Measures Ac And Dc Current Powers Off Automatically After 30 Minutes Of Non-Use To Conserve Battery Life Low Battery Indicator And Easily Accessible Battery Compartment Includes Carrying Case (Instruction Manual), Straight Input Test Leads, And 2 X Aaa Batteries Can Be Used With Magnetic Hanger Cat. No. 69417 (Sold Separately)
Specifications Type: Clamp Meter
Application: Measures Current To 2000A Ac/Dc
Special Features: Low Impedance (Loz) Mode; Dedicated Mode For Capturing Inrush Current; Integrated
Non-Contact Voltage Tester Material: Plastic/Electronics Batteries: 2 X Aaa
Auto-Power Off: Yes Jaw Size: 2'' (5 Cm) Drop Protection: 6.6' (2 M) Display: 6000 Count Lcd
Functions: Audible Continuity, Capacitance, Diode Test, Frequency & Duty Cycle, Min/Max Feature, Data Hold Capability, Inrush Current, Low Impedance
Voltage: 1000V Ac/Dc Frequency: 500Khz Current: 2000A Ac/Dc Capacitance: 6000µf Ohms (Resistance): 60M?
Ac Voltage: 1000 Dc Voltage: 1000 Dc Polarity Indicator: Yes Dc Micro-Amp: No Ingress Protection: Ip40 Standard: Cat Iv 600V, Cat Iii 1000V
Included: Carrying Case, Instruction Manual, Straight Input Test Leads, Batteries
Overall Length: 10.39'' (26.4 Cm) Overall Height: 1.70'' (4.3 Cm) Overall Width: 3.90'' (9.9 Cm)
Weight: 17.6 Oz (499 G) Upc: 092644692352
Warnings Read, Understand, And Follow All Instructions, Cautions And Warnings Attached To And/Or Packed With All Test And Measurement Devices Before Each Use Before Each Use, Verify Meter Operation By Measuring A Known Voltage Or Current Never Use The Meter On A Circuit With Voltages That Exceed The Category Based Rating Of This Meter Always Adhere To Local And National Safety Codes. Use Personal Protective Equipment To Prevent Shock And Arc Blast Injury Where Hazardous Live Conductors Are Exposed







